"*" indicates required fieldsDate Day Month YearCustomer & Loader DetailsCompanyLoader Make and modelMachine Rego or Fleet #Site / LocationService / Calibration Frequency Monthly Quarterly Six Monthly Annual OtherOtherSystem DetailsLoadrite model & serial #Loader hour meter (hrs)Indicator S/W Ver:Power supply voltageLoadcell ValuesLiftReturnTrigger TypeMaintenance ChecklistPlease select In cab - check Indicator secure, wiring secure and tidy, rem add functional In cab - upgrade to latest indicator s/w, check rod and bore correct External - check all cables, secure, damage free, repair or replace as required External - bleed transducers if accessible, secure hydraulic hoses External - check rotary trigger, FEL cable tension and mounting security, Loader - finger and bolt condition, electrical superset connection, corrosion, loose pins External - check grease, pins, loader operation and general damage or issues likely to impact accurate weighing FEL truck - remove load cell covers, check load cell bolt tension and values, cable routing and strain relief, connector water ingress, remove material between cab Data - check printer quality, replace ribbon if needed, modem - check secure and signal strength, note dB down Back up - save print cal and clone as left to dropbox Complete calibration process tests and complete record sheet - Fit cal next due stickerSelect AllUpload File or Photo Drop files here or Select filesAccepted file types: pdf, png, jpg, gif, bmp, jpeg, Max. file size: 512 MB.NotesHiddenFileMax. file size: 512 MB.Calibration RecordsIn order to pass the calibration procedure, every lift has to be within the following limits (L series - increment size set to 20kg): +/- 1.00%In order to pass the calibration procedure, every lift has to be within the following limits (LR920 - increment size set to 5kg): +/- 10.0%Test weight usedTonne/KgZERO (as found)Lift 1Lift 2Lift 3ZERO CalibrationLift 1Adjusted Lift 2Lift 3SPAN CalibrationLift 1Adjusted Lift 2Lift 3Name & SignatureName of Loadrite Service Engineer First Last I/We hereby confirm that the loadrite weighing system installed on the above mentioned vehicle / installation performs within the specification parameters.Signature*Send a copy of the report to the email address below: How happy was the customer with the Service and Calibration in your opinion?Very happyHappyNeutralNot HappyVery unhappy